AD

Tuesday, September 6, 2011

Proposal for conducting Energy Audit


Proposal for conducting Energy Audit

Reference to the visit of CEO Wellbeinggreen and Sales Coordinator at your site on August 9, 2011 for the site assessment of your factory. I would like to present the IR thermal Imaging Report of the site which is derived from the customize software of FLUKETi10 IR imaging camera.

Considering the situation, I would like to draws  your attention toward the Energy auditing of your site. An Energy Audit is an analysis of energy consumption for energy conservation in a system. Most of the time, the amount of energy consumed by the system is more than actually required for it. Use of old equipment and motors, Power factor issues, under sizing / over sizing of wire and overheating of equipment are the major causes of energy losses in the system.

Energy Audit identifies opportunities and provides recommendations for energy and cost savings. Recommendations can range from improved energy management, load management to appropriate energy-saving technologies and structural improvements. It also recommends predictive and preventive maintenance of the electrical infrastructure and mechanical machines to reduce the chances of any future mishap.
We would like to recommend you the Preliminary Energy Audit for the site. Preliminary Energy Auditing  includes:

o       Description of Predictive and Preventive measure for electrical distribution network to avoid phase unbalancing and  any future  mishap
o       Provision of an itemized and prioritized list of recommendations to reduce energy consumption
o        Description of technology if needed to be implemented.
o       Analysis of 24 months bills
o       Preparation of monthly or seasonal energy consumption profiles
o       IR thermal Imaging Report(detailed report of major problematic areas)
o       Measurement of light levels(according to requirement of job description/area)
o       Detailing of key equipments

On submitting the report of Preliminary energy audit, you will be able to discover sources of energy waste and apply energy efficiency measures to different types of systems employed at your site. This energy audit will save almost 5% to 7% of energy. If the recommended measures are done with proper load management and equipment replacement the energy saving can be up to 15%-20%. The overall benefits you get of conducting energy audits are:

·         Financial: By reducing expenditure on energy, maintenance cost and savings.
·         Operational: By optimizing the operation of system or a process.

During the initial energy assessment  we found that the site is facing serious energy efficiency issues which is causing  high energy consumption at your site. According to information gathered during the visit, the site has an energy consumption of approximately 55 KW and the major part of energy consumption is due to the motors. We suggest that much energy can be saved if the load on the motor is properly managed and variable frequency drives are used with it. A considerable amount of energy will be saved if the sizing of motors and wiring are checked.  A randomly checked IR image IR000017.IS2 shows that the wiring is overheated and cause any major mishap in future.

Currently the site is utilizing 2 gas GENSET on 70% for the entire load. We recommend that if Energy audit is done with appropriate energy efficiency measures, the  energy consumption can be reduced and load can be achieved by using only one GENSET on 90 %.This step will result in increase efficiency of gas GENSET and decrease fuel consumption. 

Wellbeinggreen is keen to cooperate with you, however we will be requiring your assistance in gathering data from the site these includes, at least two years of all types of energy bills, Building fabric, Details of Equipments, processes and types of energy used. I have also attached the Energy Audit flyer for your consideration.

If you want to proceed with this offer please do not hesitate to discuss it with me.

Looking forward to a positive reply.

With Regards

Engr.Sana Rizwan | Energy Auditor & Customer Support Executive
Wellbeinggreen (Pvt.) Limited.
Phone:34322723-114
Skyp ID:sana.wellbeinggreen